2026-08-22Corti achieves ISO/IEC 270012026-08-22Geisinger case: 70% faster prior auth TAT2026-08-22Infinitus SOC 2 Type II compliance2026-08-22AKASA HITRUST/SOC 2 and 100% pre-bill review2026-08-22Infinitus 2025 recap: 1.17M patients automated2026-08-22HIPAA/SOC 2 Type II; recordings deleted2026-08-19Luma-PCC partnership to bring AI-enabled communications to 300+ pediatric practices2026-08-15Glass ranks top-tier on ARISE NOHARM clinical safety benchmark2026-08-15ISO 27001, HIPAA, 7+ FDA 510(k)s documented2026-08-15UpToDate integrated into Epic EHR/MyChart and ambient AI workflows2026-08-06UpToDate Expert AI adopted by ~2,500 U.S. hospitals and health systems2026-07-292.7M weekly interactions; US CAB launch2026-07-23Anterior-Stellarus partnership2026-07-23Strategic partnership with Stellarus to enable real-time AI-driven prior authorization for health plans2026-07-22Waystar Q2 2026 beat; AI anomaly detection traction2026-07-21Patient Pipeline: AI-powered new patient acquisition from ad spend to booked care2026-07-21Luma launches AI Patient Pipeline for new patient acquisition2026-07-07SMART on FHIR + Epic Toolbox integration2026-06-30Nature Health SAFEMOM study shows Ada improves health-seeking behavior on MomConnect2026-06-26Modality Partnership (NHS) rolls out Heidi across 53 sites in the UK's largest clinical deployment of ambient AI2026-06-26NHS Modality Partnership rollout2026-06-24Roche acquires PathAI for ~$1B to bolster AI-based diagnostic algorithms2026-06-24Assort Health raises $120M Series C at $1.2B valuation2026-06-15Thoreau Group signs $12B agreement to take control of Ensemble Health

Every claim we hold, and how far we can stand behind it.

142 claims across 39 products. 30% are confirmed against the source text by the evidence gate; 39% come from a class with no vendor interest. Everything below is browsable, filterable, and available as JSON.

Evidence classClaimsConfirmedWhat it can support
Peer-reviewed study195Independent review before publication. The only class that survives a sceptical committee unaided.
Regulatory filing40A statement made to a regulator, where being wrong has consequences.
Independent report329Analysis by someone with no stake in the sale.
Customer case43A real deployment, but selected and framed by someone with an interest.
Press release6323The vendor's own announcement. Useful for dates and facts, not for outcomes.
Vendor page202Marketing copy. Establishes what is claimed, never that it is true.

Showing 19 of 19 matching claims (142 in the full corpus) · 26% of this selection is confirmed · clear filters

  1. Real-world AI scribe study (JMIR 2026) participant on Heidi: My hospital has been piloting Heidi, and I have used it extensively in the emergency department (ED)

    Heidi ScribePeer-reviewed studyConfirmedOpen source ↗
    Provenance
    Claim ID
    clm_07d8295a7406b9118434
    Version
    1
    Workflow
    Ambient Clinical Documentation
    Dimension
    evidence strength
    Retrieved
    2026-08-27
    Reviewer
    healthit-gate-v1
    Source URL
    https://pmc.ncbi.nlm.nih.gov/articles/PMC13472498/
  2. Peer-reviewed Nature Health study (SAFEMOM) of Ada integrated into South Africa's government-run MomConnect WhatsApp maternal health platform found safe health-seeking behavior rose nearly a third and appropriate care-seeking rose more than 40%; an independent physician panel rated Ada's recommendations safe in 98% of cases

    Provenance
    Claim ID
    clm_e424d6e33e196547ba29
    Version
    1
    Workflow
    Clinical Evidence & Decision Support
    Dimension
    evidence strength
    Retrieved
    2026-08-27
    Reviewer
    healthit-gate-v1
    Source URL
    https://doi.org/10.1038/s44360-026-00125-x
  3. JMIR Med Inform 2026 prospective study: Abridge was chosen as the AI platform and integrated with the Epic EMR at Hawaii Pacific Health Medical Group.

    AbridgePeer-reviewed studyConfirmedOpen source ↗
    Provenance
    Claim ID
    clm_a5941d994b2af01d6698
    Version
    1
    Workflow
    Ambient Clinical Documentation
    Dimension
    evidence strength
    Retrieved
    2026-08-27
    Reviewer
    healthit-gate-v1
    Source URL
    https://pmc.ncbi.nlm.nih.gov/articles/PMC13289844/
  4. JMIR Med Inform 2026: Abridge was chosen as the AI platform and integrated with the Epic EMR.

    AbridgePeer-reviewed studyConfirmedOpen source ↗
    Provenance
    Claim ID
    clm_00b51ce1cd925912e9d6
    Version
    1
    Workflow
    Ambient Clinical Documentation
    Dimension
    interoperability
    Retrieved
    2026-08-27
    Reviewer
    healthit-gate-v1
    Source URL
    https://pmc.ncbi.nlm.nih.gov/articles/PMC13289844/
  5. JMIR Med Inform 2026 prospective Abridge study: Signal metrics found a 21% decrease in time spent on notes per day among high users.

    AbridgePeer-reviewed studyConfirmedOpen source ↗
    Provenance
    Claim ID
    clm_2d77987ee04fa4cb752f
    Version
    1
    Workflow
    Ambient Clinical Documentation
    Dimension
    economic value
    Retrieved
    2026-08-27
    Reviewer
    healthit-gate-v1
    Source URL
    https://pmc.ncbi.nlm.nih.gov/articles/PMC13289844/
  6. Prospective multi-centre study (Open Forum Infectious Diseases, 2026) of qXR version 3 AI-based chest X-ray screening across 3 public health facilities in Chhattisgarh, India: of 2,745 CXRs screened, 363 patients were presumptive for TB and 162 confirmed cases were found (44.63% positivity among presumptive cases), and an 80.21% increase in TB case notifications was observed during the AI-implemented period versus baseline (P < .001).

    qXR (Chest X-ray AI Suite)Peer-reviewed studyUnverifiedOpen source ↗
    Provenance
    Claim ID
    clm_326a114cde5f51400f91
    Version
    1
    Workflow
    Imaging & Diagnostic AI
    Dimension
    evidence strength
    Retrieved
    2026-08-27
    Reviewer
    healthit-gate-v1
    Source URL
    https://pmc.ncbi.nlm.nih.gov/articles/PMC12810203/
  7. Multi-country head-to-head accuracy comparison (Annals of the American Thoracic Society, 2026) of 7 automated chest X-ray algorithms on 3,901 chest X-rays from India, Madagascar, the Philippines, South Africa, Tanzania, Uganda, and Vietnam found qXR achieved the WHO minimum target accuracy for a tuberculosis triage test (>=90% sensitivity with >=70% specificity), with specificity of 70% or greater at 90% sensitivity.

    qXR (Chest X-ray AI Suite)Peer-reviewed studyUnverifiedOpen source ↗
    Provenance
    Claim ID
    clm_36833a1aa15ec821791a
    Version
    1
    Workflow
    Imaging & Diagnostic AI
    Dimension
    evidence strength
    Retrieved
    2026-08-27
    Reviewer
    healthit-gate-v1
    Source URL
    https://doi.org/10.1093/annalsats/aaoag011
  8. Applied Clinical Informatics (2026): early implementation of DAX Copilot in a pediatric hematology-oncology division across 11,544 outpatient encounters (Jan-Jul 2025) found that for encounters of 40 minutes or less, median documentation time was 11 minutes with DAX versus 24 minutes without - an approximately 30% lower documentation time (95% CI 19.9-38.4%; p<0.001).

    DAX CopilotPeer-reviewed studyUnverifiedOpen source ↗
    Provenance
    Claim ID
    clm_61a71bb995cf683609ed
    Version
    1
    Workflow
    Ambient Clinical Documentation
    Dimension
    evidence strength
    Retrieved
    2026-08-27
    Reviewer
    healthit-gate-v1
    Source URL
    https://pmc.ncbi.nlm.nih.gov/articles/PMC13192280/
  9. Real-world performance evaluation of the Aidoc Medical Briefcase ICH Triage model across 101,944 non-contrast head CT examinations from 74,142 patients in a 17-facility academic health system (April 2023-April 2025) demonstrated 82.2% sensitivity, 97.6% specificity, and 96.6% accuracy for intracranial hemorrhage detection (npj Digital Medicine).

    Aidoc aiOSPeer-reviewed studyUnverifiedOpen source ↗
    Provenance
    Claim ID
    clm_c0fa19558e3ea5d6059f
    Version
    1
    Workflow
    Imaging & Diagnostic AI
    Dimension
    evidence strength
    Retrieved
    2026-08-27
    Reviewer
    healthit-gate-v1
    Source URL
    https://pmc.ncbi.nlm.nih.gov/articles/PMC12823562/
  10. NEJM AI randomized trial (Dec 2025): among 238 outpatient physicians across 14 specialties (Nov 4, 2024-Jan 3, 2025) randomized to Microsoft Dragon Ambient eXperience (DAX) Copilot, Nabla, or usual care, DAX was used in 33.5% of 24,696 visits; DAX users showed no significant change in time-in-note (-1.7%; 95% CI -9.4% to +5.9%; P=0.66) but significant improvements in burnout measures (Mini-Z +2.83; PTL -39.9) versus control.

    DAX CopilotPeer-reviewed studyConfirmedOpen source ↗
    Provenance
    Claim ID
    clm_dd375bd99918073f92db
    Version
    1
    Workflow
    Ambient Clinical Documentation
    Dimension
    evidence strength
    Retrieved
    2026-08-27
    Reviewer
    healthit-gate-v1
    Source URL
    https://pmc.ncbi.nlm.nih.gov/articles/PMC12768499/
  11. Blinded PDQI-9 evaluation (Frontiers in Artificial Intelligence, 2025) of 97 clinical encounters across five specialties compared LLM-generated ambient notes from Suki's production system against physician-authored Gold notes: overall quality scores were comparable (4.20/5 ambient vs 4.25/5 gold, p = 0.04), ambient notes scored higher on thoroughness (4.22 vs 3.80, p < 0.001) and organization (p = 0.03), and reviewers overall preferred ambient notes 47% vs 39%, though hallucinations were detected in 31% of ambient vs 20% of gold notes (p = 0.01).

    Suki AssistantPeer-reviewed studyUnverifiedOpen source ↗
    Provenance
    Claim ID
    clm_93f1e478d301f2abd57c
    Version
    1
    Workflow
    Ambient Clinical Documentation
    Dimension
    evidence strength
    Retrieved
    2026-08-27
    Reviewer
    healthit-gate-v1
    Source URL
    https://pmc.ncbi.nlm.nih.gov/articles/PMC12586549/
  12. Meta-analysis of six retrospective real-world studies encompassing 9,102 CTPA scans, all assessing the Aidoc or CINA-PE FDA-approved algorithms for acute pulmonary embolism detection, found pooled sensitivity of 93% (95% CI 88%-95%) and specificity of 98% (95% CI 93%-100%) (Cureus).

    Aidoc aiOSPeer-reviewed studyUnverifiedOpen source ↗
    Provenance
    Claim ID
    clm_15d57030cdd4dbabf213
    Version
    1
    Workflow
    Imaging & Diagnostic AI
    Dimension
    evidence strength
    Retrieved
    2026-08-27
    Reviewer
    healthit-gate-v1
    Source URL
    https://pmc.ncbi.nlm.nih.gov/articles/PMC12604435/
  13. Mayo Clinic study in J Prim Care Community Health (2025 Apr 16;16:21501319251332215, doi 10.1177/21501319251332215) found OpenEvidence 'provided accurate, evidence-based recommendations in all cases, aligning with physician plans' across five common chronic conditions, with mean scores of clarity 3.55±0.60, relevance 3.75±0.44, support 3.35±0.49, and satisfaction 3.60±0.60.

    OpenEvidencePeer-reviewed studyUnverifiedOpen source ↗
    Provenance
    Claim ID
    clm_565ce01a474e2b680115
    Version
    1
    Workflow
    Clinical Evidence & Decision Support
    Dimension
    evidence strength
    Retrieved
    2026-08-27
    Reviewer
    healthit-gate-v1
    Source URL
    https://pmc.ncbi.nlm.nih.gov/articles/PMC12033599/
  14. CERTAIN study (European Heart Journal - Cardiovascular Imaging, 2024): in 750 consecutive patients at 5 expert CCTA sites, Cleerly AI-QCT analysis improved physicians' confidence two- to five-fold at every step of the care pathway, changed diagnosis or management in 57.1% (428) of patients (P<0.001), and reduced the need for downstream non-invasive and invasive testing by 37.1% (P<0.001) versus conventional visual CCTA interpretation.

    Cleerly Coronary AnalysisPeer-reviewed studyUnverifiedOpen source ↗
    Provenance
    Claim ID
    clm_a7d0185737df3457a3b3
    Version
    1
    Workflow
    Imaging & Diagnostic AI
    Dimension
    evidence strength
    Retrieved
    2026-08-27
    Reviewer
    healthit-gate-v1
    Source URL
    https://pmc.ncbi.nlm.nih.gov/articles/PMC11139521/
  15. Journal of Investigative Dermatology study (Dulmage et al., 2021;141:1230-1235, doi 10.1016/j.jid.2020.08.027) of VisualDx's point-of-care AI system found 'The AI system achieved an accuracy of 68% in determining the single most likely morphology from the test image bank', while primary care physicians scored 36% without aids and 68% with a visual guide (P < 0.001); on 222 images across Fitzpatrick skin types the AI achieved 70% accuracy in Fitzpatrick I-III and 68% in Fitzpatrick IV-VI (P = 0.79).

    VisualDxPeer-reviewed studyUnverifiedOpen source ↗
    Provenance
    Claim ID
    clm_19dcf624d235238fa2b7
    Version
    1
    Workflow
    Clinical Evidence & Decision Support
    Dimension
    evidence strength
    Retrieved
    2026-08-27
    Reviewer
    healthit-gate-v1
    Source URL
    https://doi.org/10.1016/j.jid.2020.08.027
  16. Independent BMJ Open peer-reviewed vignette study (Gilbert et al., 2020) compared digital symptom assessment apps, including Ada, against GPs for suggesting conditions and urgency advice

    Provenance
    Claim ID
    clm_796e5c36fb879e0a483b
    Version
    1
    Workflow
    Clinical Evidence & Decision Support
    Dimension
    evidence strength
    Retrieved
    2026-08-27
    Reviewer
    healthit-gate-v1
    Source URL
    https://pmc.ncbi.nlm.nih.gov/articles/PMC7745718/
  17. Lunit INSIGHT MMG (Lancet Digital Health 2020): the AI algorithm was developed and validated on 170,230 mammography examinations from five institutions; in a multicentre, observer-blinded reader study of 320 mammograms read by 14 radiologists, AI performance (AUROC 0.940) significantly exceeded radiologists without assistance (AUROC 0.810, p<0.0001), and AI assistance improved radiologists' performance to AUROC 0.881 (p<0.0001).

    Lunit INSIGHTPeer-reviewed studyUnverifiedOpen source ↗
    Provenance
    Claim ID
    clm_9953a345495ad65fe703
    Version
    1
    Workflow
    Imaging & Diagnostic AI
    Dimension
    evidence strength
    Retrieved
    2026-08-27
    Reviewer
    healthit-gate-v1
    Source URL
    https://doi.org/10.1016/S2589-7500(20)30003-0
  18. Cluster-randomized controlled trial in J Med Libr Assoc (2019 Apr 1;107(2):151-162, doi 10.5195/jmla.2019.581) evaluated VisualDx as a clinical evidence technology for skin problems in primary care: 'Thirty-two PCPs and 433 patients participated', and time from index visit to skin problem resolution was similar in both groups (hazard ratio=0.92; 95% CI 0.70, 1.21; p=0.54).

    VisualDxPeer-reviewed studyUnverifiedOpen source ↗
    Provenance
    Claim ID
    clm_fa1a96f540b206b3d969
    Version
    1
    Workflow
    Clinical Evidence & Decision Support
    Dimension
    evidence strength
    Retrieved
    2026-08-27
    Reviewer
    healthit-gate-v1
    Source URL
    https://pmc.ncbi.nlm.nih.gov/articles/PMC6466492/
  19. PLATFORM trial (JACC 2015): in 584 patients with suspected coronary disease, FFRCT-guided care reduced mean total medical costs by 32% in the planned-invasive stratum versus usual care ($7,343 vs $10,734; p<0.0001) over 90-day follow-up.

    HeartFlow Analysis (FFRct)Peer-reviewed studyUnverifiedOpen source ↗
    Provenance
    Claim ID
    clm_d313d88fef3ff93bd06f
    Version
    1
    Workflow
    Imaging & Diagnostic AI
    Dimension
    evidence strength
    Retrieved
    2026-08-27
    Reviewer
    healthit-gate-v1
    Source URL
    https://doi.org/10.1016/j.jacc.2015.09.051
Know a source we are missing?

Open to everyone — no account needed. This is a non-PHI service: never include patient identifiers.

We cannot action an evidence claim without something to check.